Split AC Installation (2 AC)
Split AC installation for 2 units in one visit. Supports 0.75 ton, 1 ton, 1.5 ton and 2 ton, inverter and non inverter. Includes indoor and outdoor mounting, standard piping connection, vacuum, leak test and cooling trial for both ACs. Extra materials, new wiring and civil work are chargeable.
- Earliest Appointment: Today or next business day
- Easy Reschedule: Free up to 2 hours before slot
About the service
Our Split AC Installation for 2 AC units is for homes, offices, clinics and shops that want two Split ACs installed in one visit. This service supports 0.75 ton, 1 ton, 1.5 ton and 2 ton Split ACs, including inverter and non inverter models of any brand.
You can install two same ton units or two different tonnages in a single booking. Example. 1 ton + 1 ton, 1 ton + 1.5 ton, 1.5 ton + 2 ton, etc. We handle complete indoor and outdoor unit mounting, standard piping, wiring connection, vacuum and leak testing for both ACs so they cool properly from day one.
Best for.
-
Two bedrooms
-
Bedroom plus hall or cabin
-
Two office rooms or treatment rooms
-
Re installation after shifting or renovation
Our process
1. Site check and planning for both ACs
The technician inspects both rooms and suggested outdoor locations. They check wall strength, outdoor space, power point position and drain route for each unit. Based on tonnage and layout, they decide indoor mounting position and outdoor placement for both ACs.
2. Indoor unit mounting . AC 1 and AC 2
Mounting plates are fixed on strong, level walls for each room. Indoor units are positioned to avoid direct airflow on the face and to keep proper gap from ceiling and side walls. Holes for pipes and drain are marked and drilled for both ACs.
3. Outdoor unit mounting for both ACs
Outdoor units are placed on wall brackets or floor stands as per site condition. Units are leveled properly to minimize vibration. Sufficient clearance is kept around each outdoor unit for hot air throw and future service.
4. Piping, drain and wiring connection
Copper pipes with insulation, drain pipes and interconnecting cables are routed between each indoor and outdoor unit within standard length. Joints are tightened properly to avoid gas leakage. Drain pipes are set with proper slope so water flows out smoothly without dripping inside.
5. Vacuum and leak test for both systems
A vacuum pump is used on each AC circuit to remove air and moisture. Joints are checked for leaks using proper methods. This step protects the compressor and ensures stable cooling, especially important for inverter models.
6. Gas release and dual performance test
The factory charged refrigerant is released in both ACs. Each Split AC is started in cooling mode. The technician checks airflow, temperature drop, vibration, noise and drainage for both units and confirms proper operation before handover.
What we need from you
-
Two suitable indoor walls and outdoor locations finalized in advance
-
Working power sockets or MCB lines for both ACs
-
Wall brackets or outdoor stands available, or approval to install new ones
-
Ladder or safe access if any outdoor unit is at height
-
Permission for drilling holes for pipes and drain in both rooms
What is usually included . and what is extra
Included in standard installation for 2 ACs
-
Indoor mounting plate fixing for both units
-
Outdoor placement on existing brackets or stands
-
Connection of standard copper pipe length, drain pipe and interconnecting cable for each AC as per your plan
-
Vacuum and leak check for both units
-
Cooling test and basic demo
Chargeable extras as per site condition
-
Extra copper pipe length beyond standard for any unit
-
Extra drain pipe, casing or trunking
-
New outdoor wall brackets or floor stands
-
Core cutting, heavy drilling, major civil work
-
New electrical line, MCB or stabilizer
Why choose this Split AC installation service
-
Works for 0.75 ton, 1 ton, 1.5 ton and 2 ton Split ACs
-
Suitable for homes, offices, clinics and shops with two rooms
-
Handles same ton or mixed ton combinations in one visit
-
Proper vacuum and leak testing, not shortcut installation
-
Clear split between standard scope and extra material or wiring charges
Frequently asked questions
Q1. Can I install two different tonnage Split ACs in this service
Yes. You can install any combination. 0.75 ton, 1 ton, 1.5 ton or 2 ton, inverter or non inverter.
Q2. Is gas filling included
No. For a new factory charged unit, gas filling is usually not required. If a used unit needs gas topping due to earlier work, gas filling is extra.
Q3. Does this include stabilizer and new wiring
No. If you already have stabilizers and wiring, technicians will connect to them. New wires, MCB or stabilizer cost is separate.
Q4. How long does installation for 2 Split ACs take
Generally 2 to 4 hours, depending on floor level, wall type, outdoor access and pipe routing distance.
Q5. Will you fix wall finishing after drilling
Small drill points are closed roughly if required. Full wall finishing, repainting or POP work is not part of the service.
Be the first to review “Split AC Installation (2 AC)”
Booking and Dispatch
- Appointments are offered for your area in {{territory_name}}.
- You will get a confirmed time window after technician assignment.
- Technician selection uses skills required for the service.
Arrival Window
- Standard arrival window is 60 to 90 minutes around your slot.
- Delays due to weather or traffic are communicated by SMS or call.
Reschedule or Cancel
- Free reschedule or cancel up to {{free_reschedule_window_hours}} hours before the slot.
- Inside the window or technician en route. a visit fee of ₹{{visit_fee}} applies.
Access and Safety
- Ensure power, water and safe access to indoor and outdoor units.
- Provide building permissions if needed. jobs needing special access equipment may be rebooked.
Pricing and Payments
- Fixed price services show the total for the stated scope. parts that are not included are extra.
- Time and Material services charge visit plus actual time and parts. an estimate is shared for approval if parts exceed ₹{{approval_threshold}}.
- Online and UPI and cards accepted on completion.
Service Warranty
- Workmanship warranty is {{warranty_days}} days from completion.
- If the same issue reappears within warranty. we re-visit at no charge and fix our workmanship.
Parts and Materials
- OEM parts carry the manufacturer warranty. labor to fit parts follows our workmanship warranty.
- Refrigerant and consumables are billed as used for T and M jobs.
Refunds
- Prepaid fixed jobs. full refund if canceled before the free window.
- If the technician is dispatched or work has started. the visit fee is deducted.
- No refunds after successful completion of the booked scope.
What is not covered
- Damage due to voltage fluctuation without stabilizer. water ingress. pest or physical abuse.
- Civil works. painting. concealed piping. false ceiling work. unless listed in the service.
- Drain choke caused by building plumbing beyond AC drain.
- Leaks from coils or piping that require replacement. unless you approve the paid repair.








Reviews
There are no reviews yet.