Cassette AC Installation (1 AC)
Cassette AC installation service for 1 unit. Supports 0.75 ton, 1 ton, 1.5 ton and 2 ton cassette ACs of any brand. Includes indoor cassette mounting, outdoor unit installation, standard copper and drain connection, vacuum, leak test and trial run. Extra materials, wiring and civil work are charged separately.
- Earliest Appointment: Today or next business day
- Easy Reschedule: Free up to 2 hours before slot
About the service
Our Cassette AC Installation for 1 AC unit is for offices, shops, showrooms, clinics and homes that want one ceiling cassette AC installed properly for clean, even cooling.
This service covers 0.75 ton, 1 ton, 1.5 ton and 2 ton cassette ACs, inverter and non inverter, of any brand. We handle indoor cassette mounting, outdoor unit installation, copper piping, drain connection and power hookup as per standard installation scope so your new cassette AC starts cooling safely and efficiently.
Best for.
-
New cassette AC installation in cabins, reception, small halls or living rooms
-
Re installation of a cassette AC after shifting or renovation
-
Upgrading from wall AC to ceiling cassette for better air distribution
Our process
1. Site visit and planning
The technician checks.
-
Room size and layout
-
False ceiling design and height
-
Possible indoor cassette position
-
Outdoor unit location and support
-
Path for copper pipes, drain pipe and cable
They then finalise the best position for indoor cassette and outdoor unit for safe service access and proper air throw.
2. Indoor cassette positioning and support
The mounting area is marked and leveled.
-
Proper support points are identified in the ceiling structure
-
Suspension rods or brackets are fixed as per unit design
-
Indoor unit is lifted and fixed at correct height so grill is flush and level with the ceiling
Correct leveling is critical to avoid water leakage and uneven airflow.
3. Outdoor unit installation
The outdoor unit is installed at a suitable place.
-
On wall brackets, floor stand or terrace as per site condition
-
With enough gap around for airflow and future service
-
On level support to reduce vibration and noise
4. Copper piping, drain and cabling
The technician connects.
-
Copper pipes with proper flaring and insulation
-
Drain pipe with correct slope so water flows out smoothly
-
Interconnecting cable between indoor and outdoor units
Standard pipe length and drain length are included as per plan. Extra length, core cutting or heavy civil work is chargeable.
5. Vacuum and leak test
A vacuum pump is used to remove air and moisture from the piping.
All joints are checked for leaks. This step protects the compressor and cooling performance, especially for inverter cassette ACs.
6. Gas release and performance test
Factory charged refrigerant is released into the system.
The AC is started in cooling mode and the technician checks.
-
Airflow from all sides of the cassette
-
Temperature drop at outlets
-
Noise and vibration of indoor and outdoor units
-
Drainage to confirm no water is returning inside
7. Handover and basic training
You get a short demo on.
-
Using modes, temperature, fan speed and swing
-
Recommended temperature range
-
Basic filter cleaning and service gap
What we need from you
-
Final decision on cassette location inside the room
-
Accessible place for outdoor unit with permission to fix brackets or stand
-
Working electrical line, MCB and isolator as required for the tonnage
-
Permission for drilling, ceiling access and pipe routing
-
Clear area under the cassette location during work
Standard installation includes
-
Mounting of 1 indoor cassette unit
-
Installation of 1 outdoor unit on existing or new brackets or stand
-
Connection of standard copper pipe, drain pipe and cable within defined length
-
Vacuum and leak test
-
Test run and basic demo
Extra charges may apply for.
-
Extra copper pipe or drain length beyond standard
-
New wall brackets, floor stands or vibration pads
-
False ceiling cutting, heavy core cutting or major civil work
-
New electrical wiring, MCB, isolator or stabilizer
Frequently asked questions
Q1. Is this service valid for 0.75 ton, 1 ton, 1.5 ton and 2 ton cassette ACs
Yes. The installation service supports all four tonnages for inverter and non inverter cassette ACs of any major brand.
Q2. Is electrical wiring and MCB included
No. Existing ready power points are used. Any new wiring, MCB, isolator or stabilizer is treated as extra work.
Q3. Does this include gas filling
New units come factory charged. In normal installation, no extra gas is needed. If a used system needs gas top up, gas filling is charged separately.
Q4. Will you modify the false ceiling completely
Minor access cutting can be discussed. Full false ceiling modification, framing or finishing is not part of standard installation and may need a carpenter or ceiling contractor.
Q5. How long does cassette AC installation for 1 unit take
Typically 3 to 5 hours, depending on ceiling height, pipe routing distance and site complexity.
Q6. Can you reinstall an old cassette AC removed from another site
Yes. As long as the unit is in workable condition, this service can be used as re installation, with any additional repair or gas work billed separately.
Be the first to review “Cassette AC Installation (1 AC)”
Booking and Dispatch
- Appointments are offered for your area in {{territory_name}}.
- You will get a confirmed time window after technician assignment.
- Technician selection uses skills required for the service.
Arrival Window
- Standard arrival window is 60 to 90 minutes around your slot.
- Delays due to weather or traffic are communicated by SMS or call.
Reschedule or Cancel
- Free reschedule or cancel up to {{free_reschedule_window_hours}} hours before the slot.
- Inside the window or technician en route. a visit fee of ₹{{visit_fee}} applies.
Access and Safety
- Ensure power, water and safe access to indoor and outdoor units.
- Provide building permissions if needed. jobs needing special access equipment may be rebooked.
Pricing and Payments
- Fixed price services show the total for the stated scope. parts that are not included are extra.
- Time and Material services charge visit plus actual time and parts. an estimate is shared for approval if parts exceed ₹{{approval_threshold}}.
- Online and UPI and cards accepted on completion.
Service Warranty
- Workmanship warranty is {{warranty_days}} days from completion.
- If the same issue reappears within warranty. we re-visit at no charge and fix our workmanship.
Parts and Materials
- OEM parts carry the manufacturer warranty. labor to fit parts follows our workmanship warranty.
- Refrigerant and consumables are billed as used for T and M jobs.
Refunds
- Prepaid fixed jobs. full refund if canceled before the free window.
- If the technician is dispatched or work has started. the visit fee is deducted.
- No refunds after successful completion of the booked scope.
What is not covered
- Damage due to voltage fluctuation without stabilizer. water ingress. pest or physical abuse.
- Civil works. painting. concealed piping. false ceiling work. unless listed in the service.
- Drain choke caused by building plumbing beyond AC drain.
- Leaks from coils or piping that require replacement. unless you approve the paid repair.








Reviews